Direct Answer
UL 790 and ASTM E108 are essentially equivalent roof-covering fire-test standards, not two completely different fire-rating systems. Both are used to evaluate how a roof covering or roof assembly performs when exposed to simulated fire originating outside the building. The tests establish Class A, Class B, or Class C external fire-exposure classifications.
The main difference is who maintains and publishes the standard: UL 790 is maintained by Underwriters Laboratories (UL), while ASTM E108 is maintained by ASTM International. Industry and code references commonly recognize either testing route because the two standards use the same fundamental test protocols and classification criteria.
For a commercial roofing project, the important point is usually not whether the paperwork says “UL 790” or “ASTM E108” by itself. The critical issue is whether the complete roof assembly has the required fire classification for the intended application and whether the tested assembly matches the system being installed.
Who This Applies To
- Commercial property owners
- General contractors
- Roofing contractors
- Architects and specifiers
- Developers and owners’ representatives
- Facility managers
- Building-code professionals
- Insurance and risk-management teams
Not for: This comparison explains external fire-exposure testing. It does not by itself determine the complete fire-resistance rating of a building assembly or guarantee performance during an actual building fire.
1. What Is UL 790?
UL 790 is titled Standard Test Methods for Fire Tests of Roof Coverings. The current UL listing identifies Edition 9 as active, published February 18, 2022. It evaluates the relative fire characteristics of roof coverings exposed to simulated fire sources originating outside the building.
The standard includes tests involving:
- Intermittent flame exposure
- Spread of flame
- Burning brands
- Flying brands
- Rain exposure
UL 790 describes three external fire-exposure classifications:
| Classification | General Meaning |
|---|---|
| Class A | Effective against severe fire exposure and provides a high degree of protection to the roof deck. |
| Class B | Effective against moderate fire exposure and provides a moderate degree of protection to the roof deck. |
| Class C | Effective against light fire exposure and provides a light degree of protection to the roof deck. |
UL’s current standard also states that Class A, B and C roof coverings are not expected to produce flying brands under the applicable test exposure.
2. What Is ASTM E108?
ASTM E108 is ASTM International’s Standard Test Methods for Fire Tests of Roof Coverings. Its scope similarly covers roof coverings exposed to simulated fire originating outside a building and includes intermittent flame, spread of flame, burning brand, flying brand and rain tests.
ASTM E108 also establishes:
- Class A
- Class B
- Class C
The classifications correspond to severe, moderate and light external fire exposure, respectively.
3. So What Is the Actual Difference?
| Factor | UL 790 | ASTM E108 |
|---|---|---|
| Organization | Underwriters Laboratories | ASTM International |
| Purpose | External fire testing of roof coverings/assemblies | External fire testing of roof coverings/assemblies |
| Fire exposure classes | Class A, B, C | Class A, B, C |
| Flame testing | Yes | Yes |
| Burning-brand testing | Yes | Yes |
| Flying-brand evaluation | Yes | Yes |
| Rain test | Yes | Yes |
| Fundamental test protocols | Essentially the same | Essentially the same |
The International Code Council explains that ASTM E108 and UL 790 are separately maintained documents that provide the same test protocols and classification criteria.
4. Why Do You See Both Standards in Roofing Specifications?
Roofing specifications, product literature and building-code references may identify either standard because both are established methods for determining external fire-exposure classification.
For example, a specification might state that a roof assembly must achieve a Class A external fire classification and reference ASTM E108 or UL 790 as the applicable test method.
NRCA guidance similarly explains that ASTM E108 and UL 790 are separately maintained standards with the same test protocols and classification criteria.
5. The Rating Applies to the Roof Assembly
One of the most important points is that you should not interpret a Class A result as meaning that an individual membrane or roofing component is independently “Class A” in every installation.
The fire classification is associated with the tested roof assembly.
The assembly can involve components such as:
- Roof deck
- Insulation
- Underlayment
- Vapor retarder where applicable
- Adhesives
- Membrane or roof covering
- Other components included in the tested configuration
The ICC explains that the resulting classification applies to the complete roof assembly rather than simply to the roof covering material by itself.
6. Why Does the Exact Assembly Matter?
A roofing product can have a particular fire classification only when it is installed as part of the tested or approved assembly.
For example, changing:
- Insulation type
- Deck construction
- Membrane
- Underlayment
- Attachment method
- Adhesive
- Number or arrangement of layers
can potentially make the installed system different from the assembly that was tested.
UL’s roofing guidance notes that roof-system assemblies need to be constructed according to the components identified for the rated assembly; unauthorized material substitutions can affect the applicable listing.
7. What Does Class A Actually Mean?
Class A is the highest of the three external fire-exposure classifications under these standards.
It indicates that the tested roof assembly demonstrated the required performance under the severe fire exposure specified by the test method.
It does not mean that the roof is fireproof or that it will perform identically under every real-world fire scenario.
ASTM specifically cautions that its test method measures response under controlled laboratory conditions and should not by itself be used to describe the complete fire hazard or fire risk of a roof assembly under actual fire conditions.
8. UL 790 vs ASTM E108 for Commercial Roofing
For a commercial project, the practical question is usually:
“Does the specified roof assembly have the required external fire classification for this building and installation?”
Rather than asking only:
“Is this membrane UL 790 or ASTM E108?”
The project team should verify:
- The required fire classification
- The tested assembly
- The roof deck configuration
- Insulation and cover-board configuration
- Membrane type
- Attachment method
- Underlayment where applicable
- Manufacturer’s assembly identification
- Whether the proposed installation matches the tested configuration
9. How This Relates to Building Codes
Building codes can reference ASTM E108 or UL 790 when establishing external fire classification requirements for roof assemblies.
For example, ICC guidance explains that roof assemblies can be tested according to either ASTM E108 or UL 790 and classified as Class A, B or C.
For a Florida commercial project, the applicable edition of the Florida Building Code and the project’s specific construction requirements should be checked rather than assuming that a particular classification is automatically required for every building.
10. What Should a GC or Owner Verify in a Roofing Submittal?
When reviewing a commercial roofing submittal, look for documentation that identifies the complete rated assembly.
Useful information includes:
- Applicable fire-test standard
- Class A, B or C classification
- Roof assembly identification
- Deck type
- Insulation configuration
- Membrane or covering
- Attachment method
- Manufacturer documentation
- Testing or listing information
If a contractor substitutes a component after approval, the team should verify that the revised assembly still has the required fire classification rather than assuming that the original approval automatically transfers to the modified system.
11. Common Mistake: Treating UL 790 and ASTM E108 as Competing Ratings
A common misunderstanding is that UL 790 represents one level of fire performance while ASTM E108 represents another.
That is generally not the correct way to interpret them.
They are separately maintained standards that provide the same fundamental fire-test protocols and classification criteria. The meaningful distinction is the standard under which the assembly was tested and documented, not an assumption that one automatically produces a higher fire rating than the other.
12. What Owners Should Ask Their Roofing Contractor
For a commercial project, ask:
- What is the fire classification of the complete roof assembly?
- Was the assembly tested under UL 790 or ASTM E108?
- What exact assembly was tested?
- Does the proposed roof match that assembly?
- Are the deck and insulation configurations the same?
- Are all substitutions approved?
- Does the project require Class A, B or C?
- Can you provide the manufacturer’s assembly or listing documentation?
These questions help prevent a situation where an individual roofing component is assumed to have the same fire performance as a complete tested roof assembly.
Bottom Line
UL 790 and ASTM E108 are essentially equivalent external fire-test standards for roof coverings. Both evaluate roof assemblies under simulated external fire exposure and establish Class A, Class B or Class C classifications. The primary difference is that UL 790 is maintained by UL while ASTM E108 is maintained by ASTM International.
For commercial roofing, the most important issue is the complete tested roof assembly, not simply whether a product brochure says UL 790 or ASTM E108. Verify that the installed assembly matches the tested configuration and that its fire classification satisfies the applicable project and code requirements.
Related Questions
- What roofing submittals should a GC expect from a commercial roofing subcontractor?
- How does roofing sequencing affect the overall commercial construction schedule?
- How should a GC evaluate roofing value-engineering proposals without increasing water-intrusion risk?
Sources
- UL Standards & Engagement — UL 790, Edition 9
- ASTM International — ASTM E108, Standard Test Methods for Fire Tests of Roof Coverings
- International Code Council — Guidelines for Complying With Building Code Requirements for Roof Assemblies
- NRCA — Roof Assembly Fire Classification Guidance
Last reviewed: October 2026
Related Resources
What Is a Pre-Installation Roofing Conference?
Need Commercial Roofing Help?
ShieldLine Roofing can help commercial property owners, developers and general contractors evaluate roof-system specifications, submittals, fire classifications and installation requirements.
Disclaimer: This information is provided for general educational purposes and is not building-code, engineering, fire-safety, insurance, legal, or specification advice. Always verify the applicable code edition, project requirements, manufacturer’s tested assembly and approval documentation with the appropriate professionals.