Direct Answer
TAS 105 is a Florida Building Code test procedure used to measure the field withdrawal resistance of roofing fasteners. It determines how much force a fastener can withstand before pulling out of the roof deck or substrate. The test helps establish whether the existing deck can provide adequate fastener-holding strength for a mechanically attached roofing system exposed to wind-uplift forces.
TAS 105 is particularly important during commercial reroofing projects in Florida’s High-Velocity Hurricane Zone (HVHZ), where field withdrawal testing is used for applicable mechanically attached roofing systems. Outside the HVHZ, TAS 105 or an accepted alternative may be required, depending on the applicable Florida Building Code provisions, roofing assembly, project specifications, and local building department requirements.
Who This Applies To
- Commercial property owners planning a roof replacement.
- Roofing contractors installing mechanically attached roofing systems.
- Facility managers responsible for existing roof-deck conditions.
- Design professionals verifying attachment capacity for Florida wind loads.
1. What Does TAS 105 Measure?
TAS 105 evaluates the actual withdrawal resistance of a fastener installed in a particular roof-deck material. A qualified professional uses an appropriate pull tester to apply force to the fastener and records the resistance achieved.
The results help determine whether the fastener-and-substrate combination can meet the required attachment loads. This is important because fastener performance can vary depending on deck material, thickness, condition, fastener type, and installation method.
2. How Is a TAS 105 Test Performed?
- Inspect the roof deck: Identify the substrate material, condition, and proposed attachment requirements.
- Install test fasteners: Use the specified or approved fasteners in representative locations.
- Apply withdrawal force: Use a suitable calibrated testing device to pull against the installed fastener.
- Record the results: Document withdrawal resistance, test locations, fastener details, and substrate information.
- Evaluate attachment capacity: Compare the results with the applicable design loads and approved roofing-system requirements.
Testing must follow the applicable edition of TAS 105 and project requirements. A visual inspection alone cannot establish actual fastener withdrawal resistance.
3. When Is TAS 105 Required?
TAS 105 is most commonly associated with mechanically attached roofing systems where fasteners must transfer wind-uplift forces into an existing deck.
- HVHZ reroofing: Field withdrawal testing under TAS 105 is used for applicable mechanically fastened roofing systems in Florida’s High-Velocity Hurricane Zone.
- Non-HVHZ reroofing: Testing may be required under the applicable code, product approval, or project specification. An accepted alternative, such as ANSI/SPRI FX-1, may be permitted in certain circumstances.
- Unknown or variable deck conditions: Testing may be needed to establish whether the existing substrate can provide the required fastener-holding strength.
- Design or approval requirements: The approved assembly, project engineer, or building official may specify field testing to verify attachment suitability.
TAS 105 is not automatically required for every roof replacement. The applicable code edition, building location, deck type, attachment method, and approved roofing system determine the actual requirements.
4. Why Is TAS 105 Important for Commercial Roofing?
Wind uplift places tension on roof membranes, insulation, cover boards, base sheets, and their mechanical fasteners. If the fasteners cannot hold adequately in the deck, the attachment system may fail even when the roofing materials themselves are suitable.
Field testing can reveal whether the existing deck provides adequate withdrawal resistance before the new roofing system is installed. Where results are insufficient, the project team may need to evaluate alternative fasteners, revised attachment patterns, additional fastening, deck repairs, or another approved roofing system.
5. TAS 105 vs. TAS 124
| Standard | Primary purpose |
|---|---|
| TAS 105 | Measures field withdrawal resistance of roofing fasteners in the substrate. |
| TAS 124 | Evaluates field uplift resistance of existing membrane roof systems and certain reroofing or new-construction applications. |
These tests evaluate different aspects of roofing performance and are not interchangeable. The required procedure depends on the roof system and the applicable code and approval requirements.
6. What Happens If Fastener Withdrawal Resistance Is Too Low?
If test results do not meet the required attachment criteria, the project team should not assume the proposed fastening design is acceptable. A qualified roofing professional or design professional may need to evaluate:
- Whether a different fastener is appropriate for the deck.
- Whether the fastening pattern or density can be revised within the approved system.
- Whether deteriorated deck areas require repair or replacement.
- Whether another approved attachment method or roofing assembly is necessary.
Any changes must satisfy the applicable design loads, product approval, and building department requirements.
Bottom Line
TAS 105 measures how securely roofing fasteners hold in the actual roof deck. It is especially relevant to mechanically attached reroofing systems in Florida’s HVHZ and may also be required for other projects depending on the code and approved assembly. Confirm the testing requirements before installation so the attachment design can be evaluated against the building’s required wind-uplift loads.
Related Questions
- What is a fastener pull-out test, and how many tests are required?
- What are fastener pull-out testing requirements for existing decks?
- What is TAS 114, and how does it relate to roof assembly approval?
Sources
- 2026 Florida Building Code, Test Protocols for High-Velocity Hurricane Zones — TAS 105-20
- Florida Building Commission — Product Approval Search
- ShieldLine Roofing — Fastener pull-out testing and field withdrawal resistance
Last reviewed: October 2026
Related Resources
Fastener pull-out testing requirements and test quantities
Need Commercial Roofing Help?
ShieldLine Roofing helps commercial property owners assess roof conditions, plan reroofing projects, and identify attachment and product-approval requirements. Have the existing deck and proposed fastening system evaluated before roofing installation begins.
Learn about commercial roof replacement and re-roofing
This article provides general educational information. Actual testing requirements depend on the building location, roof-deck material, attachment method, applicable code edition, and approved roofing assembly. Confirm project-specific requirements with the local building department and qualified roofing professionals.